ADT.

DISCLAIMER

DISCLAIMER: By clicking on the box below and viewing the live video broadcast, you are agreeing that the live video broadcast you are about to view is for demonstrative purposes only as reflective of the live image as broadcasted by its respective cameras. Furthermore, this live video broadcast is intended only for ADT authorized personnel. Any non-authorized personnel is strictly prohibited from viewing this live video broadcast along with any use of this application and website. Moreover, you are not allowed to share, provide, or allow your access to be used and/or accessed by anyone other than yourself, regardless of whether or not any other individual may or may not be an authorized personnel. Any use of the images or videos being broadcasted other than for the intended demonstrative purposes, including but not limited to, copying, editing, distributing, exchanging, exhibiting, renting, sharing, lending, diffusion, hiring, public display, radio or television broadcasting, or any other usage of this live video broadcast is strictly prohibited.

I hereby agree that I am an authorized personnel as described and that I will adhere to the said DISCLAIMER above

Login information

User Name: jp
Password: jp

SUPPORT CENTER

Support Center provides you technical support and download of product datas and tools.

faq

IPC FAQ Manual

Preface

Purpose
In order to deal with and solve the IPC bug during daily use for the users quickly and improve response speed, the IPC product team specially made this FAQ manual to provide users with correct solutions in time.

Attention
The manual doesn’t cover all the IPC bugs. You are welcome to contact us if there are any unknown problems and we can add them into the manual to perfect it with better service for our customers. Besides, you can contact your local retailer or after-sale engineer directly if you need more help.

This manual is for reference only.

Table of Contents

1 Network Problem
1.1 My IPC is off line from time to time.
1.2 What if network upgrade failed?
1.3 I can use “Ping” to test that the IPC is on line after upgrade, but fail to log in.
1.4 There is no code stream when I log in and the network program restarts constantly after upgrade.
1.5 It displays “Resources are limited, failed to open video” after I log in the IPC.
1.6 The video window of control installation displays “” when I log in the IPC.
2 Image problem
2.1 IR effect is bad.
2.2 The device failed to record video and snapshot.
2.3 Black edge appears in the image after upgrade.
2.4 Cross stripe or diagonal stripe appears in the image of IPC.
2.5 The IPC image is unsteady.
2.6 Gray screen appears in the IPC.
2.7 When IR light is on for the HD or SD IR dome, the image is abnormal, such as reflective image or white and unclear image.
3 Other problems
3.1 I forgot the Device IP.
3.2 I failed to log in WEB.
3.3 I failed to play the downloaded audio and video files.
3.4 Day/night config switch is invalid.
3.5 Device is leaking water.
3.6 IPC failed to recognize SD card.
3.7 Config info is mismatched with real situation after IPC working for a while.
3.8 Power adapter is unsteady.
3.9 SD card failed to store video.
3.10 I failed to save configuration.

1 Network Problem

1.1 My IPC is off line from time to time.

Solution 1: Check if the network environment is good and the network cable hole plug of IPC end is loose.
Solution 2: Check if there is IP conflict.
Solution 3: Check if the device is under normal power supply.
Solution 4: Check if the device upgraded to a wrong program.

1.2 What if network upgrade failed?

Solution 1: Log in again to check if upgrade is successful, because sometimes the progress bar doesn’t show feedback in time due to the network environment.
Solution 2: Check if the network environment is normal, and there is disconnection or power failure during upgrade.
Solution 3: Check if the program and the device are matched.
Solution 4: Re-upgrade through 3800 port of config tool (3800 needs to upgrade matched program).

1.3 I can use “Ping” to test that the IPC is on line after upgrade, but fail to log in.

Possible reason: Check if the WEB port was modified.
Solution 1: Reset the device and log in again.
Solution 2: Re-upgrade through 3800 port of config tool (3800 needs to upgrade matched program).

1.4 There is no code stream when I log in and the network program restarts constantly after upgrade.

Solution 1: Check if there is IP conflict or network disconnection.
Solution 2: Check if the device is under normal power supply.
Solution 3: Check if each connection line is loose inside the device after disassembling the camera.
Solution 4: Check if the application program of IPC is corresponding to the model, and check if N/P format program is correct.
Solution 5: Check if the control and WEB are correct, there is control running permission under WIN7, you can delete the control under C:Program Fileswebrec and eliminate IE buffer memory to reload control and WEB. Please run IE as administrator for WIN 7, you need to install QuickTime plug-in if it is non-IE browser.

1.5 It displays “Resources are limited, failed to open video” after I log in the IPC.

Solution 1: Network bandwidth is not enough; change a switcher with bigger bandwidth.
Solution 2: Too many users logging in, and it is beyond the device code stream output capacity.
Solution 3: Disconnect the network or restart the device repeatedly, see 1.1 for more details.

1.6 The video window of control installation displays “” when I log in the IPC.

Solution 1: IE permission setting is not correct, add IPC IP as trusted sites.
Solution 2: Set IE “Internet Option > Security > Custom Level > Active X control and plug-in” all enabled.
Solution 3: You need to log in IPC as an administrator in WIN 7 system for the first time.

2 Image problem

2.1 IR effect is bad.

Possible reason 1: Users didn’t use specified power supply, and failed to enable all the IR lights.
Possible reason 2: The object is so far that it is out of the range of IR light.
Possible reason 3: IR-CUT is set as color mode, which caused the front-end sensor to fail to sense IR light.
Possible reason 4: When you use the device on the table (especially rough surface), the IR light will shoot back to the lens, which will cause bad IR effect and white picture. At this moment, you should adjust the elevation angle of the lens or place the device on the edge.

2.2 The device failed to record video and snapshot.

Possible reason: “Snapshot time period” is set wrongly; storage path is not correct; “video mode” is set as off.
Solution 1: Set “video time period”, “snapshot time period” in the WEB interface; please refer to thefor more details.
Solution 2: Check if the “memory point” enable in the WEB interface is checked.
Solution 3: Check if the connection of SD and FTP of video and snapshot storage is normal, try to
connect FTP to the computer.
Solution 4: Set “video mode” as manual or auto in the WEB interface.

2.3 Black edge appears in the image after upgrade.

Solution 1: Eliminate IPC configuration or restore factory default after upgrading program.
Solution 2: Upgraded program is not corresponding to the IPC model, re-upgrade correct program.

2.4 Cross stripe or diagonal stripe appears in the image of IPC.

Possible reason 1: Bad connection for the video cable.
Possible reason 2: Strong current interference.

2.5 The IPC image is unsteady.

Possible reason: Bad connection for the video cable

2.6 Gray screen appears in the IPC.

Phenomenon: gray screen appears in the IPC, it can recover after restart under the state of power off, gray screen appears repeatedly.
Possible reason: Caused by insufficient power supply.
Solution: Check if the IPC power supply mode and power adapter are too far away from the IPC.

2.7 When IR light is on for the HD or SD IR dome, the image is abnormal, such as reflective image or white and unclear image.

Solution: Use the IR-blocking ring of the lens, or reinstall the light-blocking ring to a proper position.

3 Other problems

3.1 I forgot the Device IP.

Solution 1: Find the device IP by quick configuration tool.
Solution 2: If you know the device MAC address, you can set device IP address by modifying ARP/Ping command. Please refer tofor more details.
Solution 3: If you are Apple user, you can search the Bonjour server name of IPC and log in IPC by the browser with Bonjour service.

3.2 I failed to log in WEB.

Possible reason: User name and password are not correct, network and power adapter problems.
Solution 1: Please enter correct user name and password.
Solution 2: Check if the network cable is normal and useable, and check if the network configuration is correct or pull out the network cable plug in again.
Solution 3: Please connect default power adapter.

3.3 I failed to play the downloaded audio and video files.

Possible reason: Player problem.
Solution 1: Please download the company default player from the disc.
Solution 2: Install graphics acceleration software whose version is higher than DX8.1
Solution 3: Use MEDIA PLAYER to play the file which is converted to AVI format, install Div X503Bundle.exe plug-in.
Solution 4: Winxp operating system needs to install plug-in DivX503Bundle.exe and ffdsho-2004 1012.exe.

3.4 Day/night config switch is invalid.

Possible reason: device system time is not corresponding to computer time.
Solution 1: Single click “Camera setting > Camera property > Configuration file management > Switch according to time” in the WEB interface, set time period according to the computer time.
Solution 2: Synchronize the device time and current PC time.

3.5 Device is leaking water.

Solution 1: Users dismantled the front cover and rear cover by themselves, which were not installed properly.
Solution 2: The front cover glass is strongly pressed or crashed.
Solution3: The waterproof plug of rear cover is loose.

3.6 IPC failed to recognize SD card.

Solution 1: Check if the card slot is loose.
Solution 2: Check if the SD card in the computer is recognizable and there is no abnormality.

3.7 Config info is mismatched with real situation after IPC working for a while.

Solution 1: refresh the interface.
Solution 2: It is caused due to the modification of IPC config; it doesn’t belong to the IPC problem. Users can check what platform manages IPC or which device that the rear end is connected to. They can use check the exact reason by adopting separated checking method. Currently the PSS client and soft decoder can modify the Baud rate of some IPC, which leads to a situation where the IPC is out of control.

3.8 Power adapter is unsteady.

Solution: The high and low temperature environment is from 0℃ to 40℃ for general power adapters, the power supply will become unsteady if the adapter is beyond this range. Therefore, it is necessary to change to industrial power adapter.

3.9 SD card failed to store video.

Solution 1: Check if the SD card status is set as read only status, if so; you need to change it to read/write status.
Solution 2: Check if the SD card can be detected.
Solution 3: Check if the SD card has been damaged.
Solution 4: Check if the SD card is full, if it shows that the residual space is 0, you can format the SD card by WEB interface or check “Cover” in the “Storage management > Video control > hard disk full”  of the WEB interface.

3.10 I failed to save configuration.

Solution: First restore default device, then reconfigure.